Understand the fundamentals
An alarm identifies a condition to investigate
An alarm is a warning raised by the miner or by the monitoring system. It may mean a reading went past a set limit, a part stopped responding, a protection feature acted, or something else. An error code is a short label for a condition. Its meaning depends on the manufacturer, model and firmware, and sometimes on the stage of operation, such as startup.
Look up the exact code in the reference for that model and firmware. If a log-reading tool matches a message, treat it as a lead, not proof that a part failed. Old startup messages can stay in a log after the condition has changed. That is why the time and order of messages matter.
The last message is not necessarily the first problem
Swipe sideways to follow the full diagram →
See how it works
Separate three levels of statement
An observation is something you saw and recorded: “board 2 is absent from the status page at 10:20.” A symptom is a short summary of the unwanted behavior: “reduced output.” A diagnosis names the cause: “a particular communication component failed.” Before a diagnosis, there is often a hypothesis. That is a possible cause you have not tested yet, such as “board communication may be involved.” To get from an observation to a diagnosis, you need evidence that rules out other possible causes.
At the Miner Technician 1 level, accurate observations and clear escalation are valuable work. You do not need to invent a cause to make a report sound technical. Say what was expected, what happened, when it started and what else changed.
| Statement type | Example | What is needed next |
|---|---|---|
| Observation | Board 2 absent at 10:20 | Record where it came from and the conditions |
| Symptom | Reduced output | State what was expected and what happened |
| Hypothesis | Board communication may be involved | Evidence that rules out other causes |
| Diagnosis | A specific component failed | Investigation and checks that support it |
Connect it to the field
Example: preserve the event sequence
A log shows a temperature warning, then a shutdown, then messages about reconnecting to the network. If you report only the last message, the earlier warning gets lost. Keep the part of the log around the first abnormal entry. Where you can, also keep the normal entries just before it.
Also record any planned changes and where the machine sits among its neighbors. If several neighboring machines alarm together, they may share a cause, such as the same network switch, power feed or cooling. Do not clear counters, reboot or change settings just to make an alarm go away. Take those actions only when they are part of the authorized response.
Terms used in this lesson
- Alarm
- A condition reported by software or a device.
- Symptom
- A short summary of the unwanted behavior, such as “reduced output.”
- Cause
- The underlying reason for a problem. Naming a cause is a diagnosis, so it needs evidence, not a guess.
Optional references & further reading
Use current manufacturer instructions for the exact equipment and your site’s approved procedures. Course levels do not grant task authorization.