This is shared Avalon A-Series reference material covering 5 models. Components, supply voltage/phase, PSU, cooling and service procedures vary by model and revision. Use the exact model nameplate and OEM manual; shared examples do not establish compatibility.
Diagnosis is a discipline: read the evidence, form one hypothesis, test the cheapest thing first, and only escalate to a swap/RMA once you've ruled out cabling, power, cooling, config, and firmware.
What it means: Avalon reports numerically via the cgminer API on TCP 4028, and estats is the richest dump available. Read it top-down: SYSTEMSTATU → ECMM → ECHU → MM_STATUS → PS → PVT_T/V → GHS. Compare GHSavg (measured) vs GHSmm (theoretical) and TA vs nameplate.
Symptoms
Field procedure
What it means: estats shows ECHU[N 0 0] - one board missing/faulted. Because Avalon has per-slot addressing, a slot-swap test cleanly isolates board vs controller.
Symptoms
Field procedure
What it means: BOOTBY codes and SYSTEMSTATU tell you why. 0x02 = overheat, 0x03 = pool/DNS, 0x04 = net re-init, 0x11 = no hashrate in 5 min, 0x12 = <70% nameplate.
Symptoms
Field procedure
What it means: Avalon's PS field is a summed bitmap. Bit 1 = input under-voltage; bit 64 = output over-current (usually a hashboard SHORT); per-channel OC bits point to a specific board.
Symptoms
Field procedure
What it means: The 'Toohot' red-fault class triggers when PVT_T exceeds ~85 °C. One extreme PVT_T vs neighbors points at that sensor/ASIC rather than a whole-board heat event.
Symptoms
Field procedure